Search results for "Heart Atria"
showing 10 items of 78 documents
Factors affecting basket catheter detection of real and phantom rotors in the atria: A computational study
2018
[EN] Anatomically based procedures to ablate atrial fibrillation (AF) are often successful in terminating paroxysmal AF. However, the ability to terminate persistent AF remains disappointing. New mechanistic approaches use multiple-electrode basket catheter mapping to localize and target AF drivers in the form of rotors but significant concerns remain about their accuracy. We aimed to evaluate how electrode-endocardium distance, far-field sources and inter-electrode distance affect the accuracy of localizing rotors. Sustained rotor activation of the atria was simulated numerically and mapped using a virtual basket catheter with varying electrode densities placed at different positions withi…
Spontaneous echo contrast caused by platelet and leukocyte aggregates?
2001
Background and Purpose —Spontaneous echocardiographic contrast (SEC) is correlated to clinical thromboembolic events. We sought to determine the origin of SEC by utilizing direct analysis of left atrial blood. Methods —We examined the blood of 13 patients with and 19 without SEC. Blood samples were taken from the femoral vein and artery and from the right and left atria after transseptal puncture. Samples were incubated with fluorescence-labeled antibodies directed against the platelet (CD41a-PE, CD42b-PE, and CD62p-FITC) and leukocyte membrane epitopes (CD45-APC and CD14-FITC). The expressed epitopes were analyzed by dual laser flow cytometry immediately after blood withdrawal. Results —I…
Manifestation and ultrastructural typing of amyloid deposits in the heart
1983
Using light and electron microscopy, 65 cases of amyloid deposits in the heart were examined. Five different groups were distinguished: I. isolated atrial amyloidosis, II. senile cardiac amyloidosis, III. cardiac amyloid accompanying chronic infections and tumors, IV. cardiac amyloid accompanying plasma cell dyscrasia, V. idiopathic cardiac amyloidosis. Seen structurally, no principal differences in the precise localization of the amyloid deposits were found in any of the groups investigated. Amyloid is always deposited in the vicinity of cells with myocytic cell differentiation (i.e. the heart muscle cells, non-striated muscle cells of the vessels), whereby the relevant basement membranes …
Positive inotropic response to 5-HT in human atrial but not in ventricular heart muscle
1992
The effects of 5-hydroxytryptamine (5-HT) on force of contraction (FC), action potential (AP) and calcium current (ICa) were studied in human right atrial and left ventricular heart muscle. 5-HT exerted a concentration-dependent increase in FC in multicellular atrial preparations; the EC50 was approximately 3 x 10(-7) mol/l. Maximal increases in FC (252 +/- 58% of control values; mean +/- SEM, n = 6) were obtained at 5-HT 10(-5) mol/l. At this concentration, ICa was increased four- to sevenfold in enzymatically isolated atrial myocytes. In contrast, ventricular preparations did not respond to 5-HT; FC, AP and ICa remained unaffected. In the same preparations, FC was increased by isoprenalin…
Effect of intravenous flecainide on atrial vulnerability in man.
1985
Sixteen patients were investigated by means of programmed atrial stimulation at 2 different driving rates: 100/min and 120/min. All patients had an increased atrial vulnerability at both driving rates. After the administration of intravenous flecainide (1 mg/kg bodyweight as a bolus, followed by the same amount infused over a period of 20 minutes), the increased vulnerability was abolished in 11 and 9 patients, respectively. In the remaining patients the rate of induced atrial tachyarrhythmia decreased. These findings correlate with a significant prolongation of the effective refractory period of the right atrium and a corresponding significant shortening of its relative refractory period. …
Detection of spontaneous echocardiographic contrast within the left atrium by transesophageal echocardiography: spontaneous echocardiographic contrast
1986
Transesophageal echocardiography was performed in 314 patients over a period of 24 months using a 3.5 MHz phased-array system fitted to the distal end of a conventional 12 mm endoscope. In 12 patients (2.6%) transesophageal echocardiography could not be performed because of adverse reaction to the gastroscopic procedure. Side effects were a transient A-V block in one patient and asthmatic attack in another. Mitral valve lesions were found in 99 of 314 patients. In 9 of these 99 patients (11%), including 1 patient with mitral valve stenosis and sinus rhythm, 2 with atrial fibrillation, 3 with disc, and 3 with porcine mitral prosthesis, spontaneous echocardiographic contrast was found within …
Wave similarity mapping shows the spatiotemporal distribution of fibrillatory wave complexity in the human right atrium during paroxysmal and chronic…
2005
Introduction: The complexity of waveforms during atrial fibrillation may reflect critical activation patterns for the arrhythmia perpetuation. In this study, we introduce a novel concept of map, based on the analysis of the wave morphology, which gives a direct evidence in the human right atrium on the spatiotemporal distribution of fibrillatory wave complexity in paroxysmal (PAF) and chronic (CAF) atrial fibrillation. Methods and Results: Electrograms were recorded from a 64-electrode catheter in the right atrium of 15 patients during PAF (n = 8) and CAF (n = 7). Wave similarity maps were constructed by calculating the degree of morphological similarity of activation waves (S) at each atri…
Genetic variants associated with cardiac structure and function: a meta-analysis and replication of genome-wide association data.
2009
Context Echocardiographic measures of left ventricular (LV) structure and function are heritable phenotypes of cardiovascular disease. Objective To identify common genetic variants associated with cardiac structure and function by conducting a meta-analysis of genome-wide association data in 5 population-based cohort studies (stage 1) with replication (stage 2) in 2 other community-based samples. Design, Setting, and Participants Within each of 5 community-based cohorts comprising the EchoGen consortium (stage 1; n = 12 612 individuals of European ancestry; 55% women, aged 26-95 years; examinations between 1978-2008), we estimated the association between approximately 2.5 million single-nuc…
Assessment of atrial diastolic function in patients with hypertrophic cardiomyopathy by cine magnetic resonance imaging
2015
Purpose: This study was conducted to assess the role of atrial function by cardiac magnetic resonance (CMR) for the evaluation of diastolic physiology in patients with hypertrophic cardiomyopathy (HCM) compared to healthy controls. Materials and methods: We enrolled 23 consecutive patients affected by HCM and 43 healthy subjects as age-matched control cases (CC). CMR was performed through acquisition of cine steady-state free precession sequences using a 1.5-T scanner. Image postprocessing was carried out using Tracking Tool software. Results: Atrial volumes were significantly higher in patients with HCM compared to CC: maximum atrial volume (p = 0.007) and minimum atrial volume (p = 0.01).…
Implantation Strategy of the Atrial Dipole Impacts Atrial Sensing Performance of Single Lead VDD Pacemakers
2002
WIEGAND, U.K.H., et al.: Implantation Strategy of the Atrial Dipole Impacts Atrial Sensing Perfor-mance of Single Lead VDD Pacemakers. Intermittent atrial undersensing is observed in a considerable percentage of patients with single lead VDD pacemakers. Analyzing the 2-year data of the Saphir Multicenter Follow-Up Study, the authors investigated predictors for the occurrence of undersensing. The study included 194 patients with high degree AV block who received a VDD pacemaker system with an identical sensing amplifier. Placement strategy of the atrial dipole was left to the discretion of the implanting physician. At the final position, atrial potential amplitudes were measured during deep …